1. The main difference between fixed ultrasonic flowmeter and portable ultrasonic flowmeter
(1) The applicable occasions are different. The fixed ultrasonic flowmeter is used to install in a fixed position to measure the flow of fluid in a specific pipeline for a long time without interruption; the portable ultrasonic flowmeter has great mobility, mainly Used for temporary measurement of fluid flow in different pipelines.
(2) Different power supply methods. Fixed ultrasonic flowmeters require long-term continuous operation, so 220V AC power must be used. Portable ultrasonic flowmeters can use on-site AC power or have built-in rechargeable batteries, which can work continuously for 5-10 hours, which is greatly It facilitates the needs of temporary flow measurement in different occasions.
(3) Some fixed ultrasonic flowmeters with different functions usually have 4-20mA signal output and other functions for remote display, but they can only store the parameters of one pipeline inside; portable ultrasonic flowmeters are only for on-site viewing at the time Generally, there is no output signal function for the flow rate and the accumulated flow rate in a short period of time. However, in order to facilitate the measurement of the flow of different pipelines, it has a rich storage function, which can store the parameters of different pipelines at the same time for use at any time.
2. The power supply mode of the fixed ultrasonic flowmeter and the portable ultrasonic flowmeter transducer is different
It can be divided into three types of ultrasonic flowmeters: clamp-on type, plug-in type, and pipe segment type.
(1) The externally attached and externally clamped ultrasonic flowmeter is an ultrasonic flowmeter that was produced earlier, is familiar to users and has a better application. The installation of the transducer does not require pipeline interruption, and it is ready to use. It fully embodies the ultrasonic flowmeter. It is easy to install and easy to use. (2) Some pipes of the pipe segment type are due to poor material, poor sound conduction, or severe corrosion, gaps between the lining and the inner space of the pipe, etc., resulting in serious attenuation of the ultrasonic signal. The external ultrasonic flowmeter cannot be measured normally, so it has Pipe-section ultrasonic flowmeter. The tube segment ultrasonic flowmeter integrates the transducer and the measuring tube, which solves a problem in the measurement of the externally attached flowmeter. Moreover, the measurement accuracy is higher than other ultrasonic flowmeters, but at the same time, it also sacrifices the advantages of continuous flow installation of the external ultrasonic flowmeter, and requires cutting the pipe to install the transducer.
(3) Plug-in ultrasonic flowmeter is between the above two. In the installation, it can flow continuously. Use special tools to punch holes in the pipe with water, insert the transducer into the pipe, and complete the installation. Since the transducer is in the pipeline, its signal transmission and reception only pass through the measured medium, not the pipe wall and lining, so its measurement is not limited by the pipe quality and the pipe lining material.