With temperature and pressure compensation: Temperature and pressure compensation usually means that the data measured by the instrument is the result under the condition that the temperature is 25 degrees and the pressure is a standard atmospheric pressure. Usually the temperature and pressure at the measurement site are different from the standard, so general instruments can measure the site Temperature and pressure, and then automatically compensate the measurement results through calculation formulas.
The advantages of temperature and pressure compensated gas steam vortex flowmeter are as follows:
1. The big advantage is that it has particularly good anti-vibration performance, no zero point drift, and high reliability.
2. The sensor has strong versatility, which makes the sensor have good interchangeability. Advanced CNC equipment is used to process the surface body and vortex generator of the sensor to ensure the processing accuracy, thereby making the parts (especially the vortex generator) universal. It has strong performance, so that the repeatability and accuracy of the sensor will not be affected by the replacement of parts; it can generate a strong and stable vortex signal.
3. Within a certain Reynolds number range, the flow characteristics are not affected by fluid pressure, temperature, viscosity, density, and composition, but are only related to the shape and size of the vortex generator.
4. Output pulse signals or analog signals proportional to the flow rate, without zero drift, high precision, and convenient for networking with computers.
5. Simple and solid structure, no moving parts, high reliability, easy to use and maintain.
6. The detection element does not come into contact with the medium, has stable performance and long service life. The sensor uses a detection probe and is installed separately from the vortex generator, and the high-temperature-resistant piezoelectric crystal is sealed in the detection probe and does not come into contact with the measured medium, so the vortex flow meter has the characteristics of simple structure, good versatility and high stability.
7. Wide measuring range, with range ratio up to 1:10.
8. No compensation is required when measuring volume flow. The signal output by the vortex street is actually linearly related to the flow rate, that is, proportional to the volume flow. The purpose of pressure and temperature compensation is to obtain the density of the fluid, which is multiplied by the volume flow rate to obtain the mass flow rate. If the volume flow rate of the gas is measured, compensation is not required.