1. application:

 

Steam flow meter vortex type is the preferred device for measuring superheated and saturated steam flow. Its standard temperature resistance is 250℃, and the highest temperature resistance can reach 350℃. The measurement accuracy is as high as 1%. Because the density of steam changes with the temperature, the vortex flowmeter with temperature and pressure compensation can measure the flow, temperature, and pressure of the gas at the same time. The display unit can be a mass unit, such as KG/H, or Ton/H, which ensures the accuracy of the measurement. The power supply mode of the device is normally: 24VDC+battery dual power supply, output with 4-20MA, Modbus communication, which can ensure remote connection to the control system and realize flow monitoring, control, management, statistics, etc.

 

Air vortex flow meter

Threaded vortex flowmeter

Flange vortex flowmeter

Vortex flowmeter high pressure

Split vortex flowmeter with temperature and pressure

Temperature and pressure compensation vortex flowmeter

Flange connection vortex flowmeter1

Split type vortex flowmeter with temperature and pressure compensation

Insertion vortex flowmeter

 

2. Selection and installation connection method:

 

The maximum temperature resistance of the integrated type is 250℃, and it can be a pulse type, an integrated display type, and an integrated temperature and pressure compensation type.

The split type's maximum temperature resistance is 350℃, and it can be a common type with a display, which is a pulse type + flow integrator. The temperature and pressure compensation type is a pulse type + flow meter integrator + pressure transmitter + temperature sensor.

The sensor material of the steam flow meter vortex type is generally: SS304 or SS316. For pipe diameters of DN50 (2") and below, you can choose any of the three connections: thread, flange connection, and flange clamp. For pipe diameters of DN100 and above, you can also choose the insertion type.

 

3. The menu functions and parameter meanings are shown in the following table:

 

number

Menu display

meaning

Selection of numeric range

1

Q Unit

m3/h

Flow unit selection

(default 0)

0: m3/h algorithm 2

1: m3/m automatically adds N

2: l/h

3: l/m

4: t/h

5: t/m

6: kg/h

7: kg/m

2

Q Mode

Qvw actual

Algorithm to choose

(default 0)

0: Qvw actual Actual volume flow

(non-gas or liquid)

1: Qm[dw] mass flow

(working condition density)

2: Qvn[@TnPn]

standard gas volume flow

3: Qmg[dn@TnPn] mass flow

of gas (standard density)

4:Qm steam[T] steam

temperature compensation

5: Qm steam[P] steam

pressure compensation

6: Qm steam[T&P] temperature

and pressure compensation

of superheated steam

7: Special Mode

(for user customization)

3

Q Factor

K [P/m3]

XXX. XXXXXXXX

Flow Factor

(default 3600)

Set the flow coefficient of the instrument, not to be 0

4

Density

[kg/m3]

XXXX. XXXX

Density is set

(default 1000)

This must be set for algorithms 1 and 3

The unit is kg/m3, not 0

5

Q20mA

m3/h

XXXXXX. XX

Full output flow

(default 1000)

The value must be set

and must not be 0,

Units are the same as flow units

6

Q cut-Zero

[%]

XX. X

Set the percent of cut flow and full flow

The value is between 0 and 20,

and the default is 1.0 %

7

Q Up Al

m3/h

XXXXXX. XX

Upper limit alarm flow

(default 990.0)

You don't have to set it,

it's usually not 0,

Units are the same as flow units

8

Q Dn Al

m3/h

XXXXXX. XX

Lower limit alarm flow

(default 10.0)

You don't have to set it,

it's usually not 0,

Units are the same as flow units

9

Damp S

[S]

XX

Output current

Damping time

(default is 4s)

the damping time is to avoid large fluctuations of output current and frequency shown

The range of 2 ~ 32

10

Hart Address

(0-15)

0

Set the HART

Communication,

Address

Range from 0 to 15 (default 0)

11

Clear Q

Enter

password XX

Zero clearing cumulative quantity

To clear the cumulative value,

Enter, password 70,

And press the "E" key

 

4. Split type with temperature and pressure compensation:

 

 

5. FAQ:

 

1. Q: Is the installation and setting of the pipeline vortex meter simple?

A: Yes, it is very simple. We will calibrate the equipment and set the parameters according to the parameters you provide when it leaves the factory. You can install it and use it after receiving the goods. If you need to update the settings, we provide the installation and use instructions, or our professional engineers will remotely guide you to install and debug.

 

2. Q: Are you a manufacturer or a dealer?

A: We are a manufacturer. Our factory was established in 2002. So far, we have more than 20 years of R&D and production experience. Our products are exported to more than 60 countries around the world and are well-received by users.

 

3. Q: Can I take samples? What is the minimum order quantity?

A: Of course, our minimum order quantity is 1PCS.

 

4. Q: How long is the delivery time?

A: We have a large number of accessories, semi-finished products, and instrument stock materials with conventional parameters. If you need, you can tell us the procurement requirements, quantity, etc., and we will tell you the production time, transportation method, and time.

 

Hot Tags: steam flow meter vortex type, China, suppliers, manufacturers, factory, wholesale, buy, price, for sale, Orifice Flow Measurement, oxygen gas liter flow meter measures 0 8 lpm, Beverage Flow Meter, Ultrasonic Liquid Flow Meter, 0 100 mbar pressure transmitter, Rotameter Flow Meter