1. Pipe diameter: DN6-DN2800
2. Type: split type, integrated type, plug-in type (applicable to pipe diameter above DN100)
3. Lining material: neoprene, PTFE, PFA, FEP, F46
4. Electrode material: SS316L, HC, HB, Ti, Tan, Pt
5. Accuracy: 0.2%, 0.5%
6. Medium temperature: -20℃~160℃
7. Valve body material: carbon steel, SS304, SS316L
8. Power supply mode: 85VAC~264VAC, 24VDC, battery powered
9. Output mode: pulse output, 4~20Ma output, Modbus, Hart (optional)
10. Connection form: clamp, thread, flange (standard options: DIN, ANSI, JIS)
Send Inquiry
Chat Now

 

1. Features and Applicable Operating Environment:

 

A magnetic flow transmitter is suitable for use in a variety of harsh environments. Power supply options include 85V-265V AC, 24V DC, battery power, and solar power. Suppose you need to install the device in an area without electrical infrastructure and need to manage the flow meter through a control system. In that case, you can choose a battery-powered model with MODBUS protocol or a battery-powered model with pulse output. These models come standard with IP68 protection, effectively meeting your measurement and control needs.

Mag flow transmitters are instruments that can measure all conductive liquids. They occupy a key position in the measurement industry due to their high accuracy, strong stability, no obstructing components in the pipeline, low maintenance costs, and long service life.

202509111002211097

 

DN80 electromagnetic flowmeter sensor

DN400 hard rubber electromagnetic flowmeter

 

 

2. Most Popular Specifications:

 

Before purchasing an electromagnetic flowmeter, you need to customize the various components of the device based on the properties of the liquid being measured. This describes the most common configurations:

 

※For measuring non-corrosive liquids such as sewage and wastewater, a rubber lining and SS316 electrodes can be used.

 

※ For measuring sanitary liquids such as drinking water, beer, and milk, a PTFE lining and SS316 electrodes can be used. Stainless steel, such as SS304 or SS316, is recommended for the sensor.

 

※For measuring acidic liquids, a PTFE lining and Hastelloy electrodes are recommended. For measuring alkaline liquids, a PTFE lining and titanium or tantalum electrodes are recommended. Stainless steel is recommended for the housing, as corrosive molecules in the operating environment can damage the sensor housing over time. Using stainless steel will significantly extend the service life.

 

 

Integrated electromagnetic flowmeter

Remote Magnetic Flow Meter

Triple Clamp Electromagnetic Flowmeter

Thread electromagnetic flowmeter

Threaded stainless steel electromagnetic flowmeter

Insertion Electromagnetic Flowmeter

 

3. Classification:

 

※ Insertion-type Magnetic Flow Transmitter, which consists of a magnetic sensor inserted into the fluid. This type of transmitter is very suitable for use in large pipelines or open channels, with low cost of use, simple installation, and high accuracy.

 

※ Integrated online flow transmitter, which is directly installed in the flow pipeline. This type of transmitter is best suited for applications with low flow rates or where the fluid is abrasive or corrosive. In-line flow transmitters are also typically more compact than insertion-type flow transmitters, making them easier to install and maintain.

 

※ Separate online flow transmitter, the sensor is installed in the pipeline, the converter and the sensor are separated (the standard configuration is 10*2 cable, but the cable length can be customized). This type is more suitable for installation in deep wells or sites with relatively high pipeline positions, especially in deep wells, and can be made with an IP68 protection level, so that if there is water in the deep well, it will not affect the normal operation of the instrument.

 

4. Size Chart:

 

 

Electromagnetic flowmeter size chart

 

DN

L

L1

H

H1

D

D1

b

N-Φ

Bolt

Weight

(kg)

10

140

76

245

65

95

65

14

4-Φ14

M12

4

15

200

76

225

70

95

65

14

4-Φ14

M12

5

20

200

76

235

75

105

75

16

4-Φ14

M12

6

25

200

76

235

75

115

85

16

4-Φ14

M12

7

32

200

76

250

85

140

100

18

4-Φ18

M16

8

40

200

76

260

95

150

110

18

4-Φ18

M16

9

50

200

76

270

100

165

125

20

4-Φ18

M16

10

65

250

76

285

110

185

145

22

8-Φ18

M16

12

80

250

76

295

120

200

160

24

8-Φ18

M16

14

100

250

100

316

130

220

180

26

8-Φ18

M16

15

125

250

140

330

145

250

210

26

8-Φ18

M16

18

150

300

170

350

285

240

65

28

8-Φ22

M20

23

200

250

230

420

190

340

295

24

8-Φ22

M20

27

250

450

280

295

220

395

350

26

12-Φ22

M20

38

300

500

290

540

240

445

400

28

12-Φ22

M20

48

350

550

300

550

285

505

460

28

16-Φ22

M20

65

400

600

360

635

305

565

515

30

16-Φ26

M24

80

450

600

360

720

326

615

565

30

20-Φ26

M24

100

500

600

360

750

335

670

620

32

20-Φ26

M24

120

600

600

356

825

410

780

725

36

20-Φ30

M27

210

700

700

440

950

470

895

840

36

24-Φ30

M27

300

800

800

500

1080

530

1015

950

38

24-Φ33

M30

400

900

900

550

1175

575

1115

1050

42

28-Φ33

M30

500

1000

1000

610

1285

670

1230

1160

44

28-Φ36

M33

700

1200

1200

730

1500

750

1405

1340

40

32-Φ33

M30

850

1400

1400

800

1700

840

1630

1540

44

36-Φ36

M33

1100

1600

1600

900

2100

975

1830

1760

48

40-Φ36

M33

1500

1800

1800

1000

2600

1300

2045

1970

50

44-Φ39

M36

1900

2000

2000

1100

2800

1400

2265

2180

54

48-Φ42

M39

2300

2200

2200

 

 

 

2475

2390

60

52-Φ42

M39

2850

2400

2400

 

 

 

2885

2500

62

56-Φ48

M42

3330

2600

2600

 

 

 

2905

2810

64

60-Φ48

M42

3895

2800

2800

 

 

 

3115

3020

68

64-Φ48

M42

4950

3000

3000

 

 

 

3315

3220

70

68-Φ48

M42

5600

 

5. Workshop Production Diagram:

 

Magnetic flow sensor

Rubber Lined Magnetic Flow Sensors

PTFE Lined Magnetic Flow Sensors

Large pipe magnetic flow sensor

 

6. Lining Options:

 

The selection of the lining of the Magnetic Flow Transmitter is very important: according to the characteristics of the measured liquid, such as the temperature of the medium, corrosiveness (PH value), whether the liquid contains impurities, etc., selecting the most suitable lining material is key to ensuring that the flowmeter's working life is key to measurement accuracy.
Available lining materials are as follows:

lining Features
Neoprene Lining *Oil resistance, solvent resistance, oxidation resistance, corrosion resistance to general acid, alkali, salt and other media, but not corrosion resistance to oxidizing media.
* Has excellent elasticity and wear resistance. But cold resistance is poor.
*Scope of application: 1.0°C-80°C non-strong acid, strong alkali, strong oxidizing medium. Can measure less abrasive sewage, mud, and slurry.
polyurethane rubber * Has excellent wear resistance and elasticity. However, its acid and alkali resistance is poor, so it cannot be used in water mixed with organic solvents.
*Scope of application: -2.5 degrees -60 degrees, suitable for neutral and strong abrasive pulp, coal slurry, mud, paper pulp, domestic sewage, waste water.
Polytetrafluoroethylene (PTFE) *PTFE is the material with the most stable chemical properties among plastics; it is resistant to boiling hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali, and various organic solvents, but it is not resistant to chlorine trifluoride, high temperature oxygen fluoride, large flow liquid fluorine, liquid Corrosion by oxygen and ozone.
B. Poor wear resistance and negative pressure resistance.
C. Scope of application: -25 degrees to -140 degrees, strong corrosive substances such as concentrated acid and alkali, drinking water, milk, beer, beverages, and other sanitary media.
Fluorinated Ethylene Propylene (F46) * Hydrophobic and non-stick.
*Corrosion resistance is second only to PFA.
*When the negative pressure resistance requirement is high, a metal mesh can be installed to improve the negative pressure resistance capacity.
* Poor abrasion resistance.
*Scope of application: -25°C-100°C non-strong abrasive media, sanitary media.

 

7. Electrode Type:

 

Electrodes material

Main performance and application

SS316L

Used for industrial water, life water, sewage, etc, with weak corrosion; applicable to the petroleum, chemical, metallurgy industries, and municipal and environmental protection fields;

 

HB

With good corrosion resistance performance to all concentrations of hydrochloric acid below the boiling point; also resist sulfuric acid, phosphoric acid, hydrofluoric acid, organic acid, and other non-oxidizing acids, alkaline, and hydrochloric acid, etc.

 

HC

Resist non-oxidizing acid, such as the mixture of nitric acid/chromic acid and sulfuric acid; and resist oxidizing salt, such as Fe3+, Cu2+, and other oxidizing agents like hypochlorite solution and seawater, etc.

Titanium

Resist seawater, kinds of chlorides, hypochlorite, oxidizing acid(including nitrosonitric acid), organic acid, alkali, etc, but not resist purified reductic acid(sulfuric acid, hydrochloric acid); Corrosion will reduce greatly when it has only oxidizing agent(like nitric acid and ionic mediums with Fe, Cu) in the acid.

Tantalum

Good corrosion-resistant property, similar to glass; it could almost resist all chemical media (including boiling hydrochloric acid, nitric acid, and sulfuric acid below 17 °C5), but not hydrofluoric acid, strong sulfuric acid ,and alkali.

Platinum-iridium alloy

 

Used for all chemical substances, resistant to corrosion (such as acid, alkali, various salts), but not resistant to aqua regia.

 

8. Check the video:
All of our products will be checked one-to-one before leaving the factory to ensure that the pass rate of the flowmeter is 100% after leaving the factory, and the accuracy meets international standards:

 

FAQ:

1. Q: How about the precision of your products?

 

A: The accuracy of our electromagnetic flowmeter is 0.5%, and the highest can reach 0.2%.

 

2. Q: What are the materials of the watch body?

 

A: The main materials are: carbon steel, SS304, and SS316. The most suitable sensor material can be selected according to the characteristics of the medium and the current site environment, or customer requirements.

 

3. Q: Can I choose to order samples? How many PCS is the MOQ?

 

A: Yes, our MOQ is 1PCS

 

4. Q: What shipping methods do you all support?


A: We can ship by sea, by air, by railway, by express, and if you have your own forwarder, we can send the goods to your designated China warehouse for free.

5. Q: What are the payment methods?

 

A: We support: TT payment, credit card online payment, Western Union payment, RMB payment, and LC payment.

 

 

If you have more questions, please contact us, we will have professional sales representatives and engineers to answer all your questions. Henan Junyuan Automation Equipment Co., Ltd. welcomes your inquiries!

Hot Tags: magnetic flow transmitter, China, suppliers, manufacturers, factory, wholesale, buy, price, for sale, Industrial Water Flow Meter, magnetic flow meter transmitter, magnetic flow meter for wastewater, 2 wire magnetic flow meter, Magnetic Water Flow Meter, insertion type magnetic flow meter